Advantech, a leading industrial communication solutions provider, has announced two new Modbus Gateways with built-in Ethernet switches, the EKI-1221D and EKI-1222D. In addition to providing transparent connectivity between Modbus (ASCII, RTU) serial devices and Ethernet based Modbus/TCP equipment, built-in Ethernet switches allow these devices to be daisy chained whilst also supporting auto bypass functionality. These new Modbus Gateways are able to fulfill flexible installation and web browser configuration requirements for remote monitoring applications. It allows auto searching for Modbus slave ID's via a configuration utility.
Daisy chain connectivity and auto bypass
Oil & Gas and water treatment applications
Class I, Division 2 certified for oil & gas applications

 
 
 
System Diagrams
Traditional Structure
Every Modbus Gateway or Ethernet enabled device connects via an Ethernet Switch.
Requires cabling.
Daisy Chain Connectivity and Auto Bypass
Built-in Ethernet switch for daisy chain connectivity offers flexible cabling and space saving capabilities.
Supports Ethernet auto bypss: preventing accidental power failure if one of the Modbus Gateway’s unexpectedly shuts down.
 
Applications
Oil & Gas
In chemical and petrochemical plants with hazardous areas, rigorous security is required to protect operators and maintain equipment. Advantech’s Modbus Gateways are UL Class I, Division 2 certified which is particularly designed for oil & gas locations. Advantech offers flexible cabling and supports Ethernet auto bypass: preventing accidental power failure in the event one of the Modbus Gateway’s unexpectedly shutting down.
Water Treatment
Proper water treatment is a very important endeavor for all industrial and public enterprises. Water treatment produces organic and mineral sludge from filtration and sedimentation. Therefore, it is important to centralize the measurement of water consumption, collect all the information on the status of the water, and remotely control the water flow level in each node (branch). Advantech’s EKI-1221D/EKI-1222D Modbus Gateway with daisy chain connectivity minimizes cabling. It also supports Ethernet auto-bypass to prevent accidental power failure.
 
 
Product Offering
Model Name
EKI-1221D EKI-1222D EKI-1221 EKI-1222 EKI-1224
Description
1-port Modbus
Gateway with
Integrated Ethernet
Cascading
2-port Modbus
Gateway with
Integrated Ethernet
Cascading
1-port Modbus
Gateway
2-port Modbus
Gateway
4-port Modbus
Gateway
Link and Download
No. of Ethernet Ports 2 2 2 2 2
No. of Serial Ports 1 2 1 2 4
Ethernet Interface 10/100M Mbps
Serial Type RS-232/422/485, software selectable
Ethernet Feature Daisy Chain Connectivity Dual Ethernet Redundancy
Configuation
Windows Configuration Utility, Web-browser console
Operating Mode Modbus RTU Master, Modbus RTU Slave, Modbus ASCII Master, and Modbus ASCII Slave modes
Baud Rate 50 bps ~ 921.6 kbps
Certification
Class I, Division 2
V V V V V
  Industrial Communication Product Portfolio
  EKI-1000 Series
Wired & Wireless Serial Device
Servers
More
  EKI-2000 Series
Entry Level Switches & Media Converters
More
  EKI-2000 Series
Managed Compact Switches
More
  EKI-4000 Series
Rack Mounted L2, L3 Ethernet Switches
More
  EKI-6500 Series
EN50155 IP40/67 Ethernet
Switches
More
  EKI-7000 Series
High Performance Managed Ethernet Switches
More
  EKI-6300 Series
Indoor 802.11n Wireless APs
More
 
Contact Advantech
For more info on these products, please call +886 2 2792 7818 or email us at inquiry@advantech.com.
Forward to a Friend!
Feel free to share the news with your colleagues, customers, partners and friends.